Characteristics
Size
48*96*80mm
Type
Floor Scale
Input
1-4 loadcells
Origin
Output
4 relay
Display
6 digit
Accuracy
0.1%F.S±2digit
Capacity
-99999 to 999999
Brand Name
MPDQ(电子)
Display Type
LED
Model Number
LH86-RRRRD
Power supply
90-260V AC
Analog output
NONE
Products Name
Loadcell indicator
Is Smart Device
no
View more
Description

MYPIN

MYPIN ELECTRICAL CO.,LTD

Add:No7,Lane 5,Str Anhe,Fengyu road ,Zhongshan ,Guangdong ,China

Whatsapp/wechat:18676133547

Products description

1.Products display


Title 1, mypin(LH86-RRRRD)loadcell indicator ,weighing c...Title 2, mypin(LH86-RRRRD)loadcell indicator ,weighing c...

2.Technical specification

Model:LH86-RRRRD

Mypin LH series 6 LED digital display Loadcells indicator

  • Input:1-4 loadcells

  • Output:4 relayS

  • Size :48*96*80mm

  • Accuracy :0.1%F.S±2digit

  • Sampling speed:≤32times/sec
  • Weight:0.35Kg
Title 3, mypin(LH86-RRRRD)loadcell indicator ,weighing c...


3.Operation/Parameter setting

  • press and hold SET key until to enter setting menu.
  • Press<< /Rst key once, LED flashing
  •  Press <</Rst once again to shift flashing LED
  • Press Up or Down key to modify data,
  • Press SET key to confirm data.
  • Press SET key to confirm,LED stop falshing.
  • press and hold SET key until to Quit menu or go to next parameter

Title 4, mypin(LH86-RRRRD)loadcell indicator ,weighing c...

4.Weight Adjustment:

  • When empty (no load),press DOWN key until ‘Oy’ flashing. release DOWN key ; PV LED displays about 0
  • Follow step 1,placing the weight of this calibration, press UP key until SV LED flashing.
  • Release UP key.refer parameter setting step to set SV LED data,SV LED data = the weight of this calibration (Equal USP parameter),
  • E.g,the calibrate weight is 50Kg, Setting SV data=50.00, the unit is Kg, Setting SV data=0.050, the unit is Ton
  • Refer Page 2(Manual)to lock adjust operation If need

5.Clear tare weight :

press << / Rst key until ‘oy’ flashs to clear tare or short external RST terminal once to clear tare
 
6.The instrument will auto-return to the measuring estate without any operation for 25 seconds
 
Note: Zero display (option,refer page 2)
when empty or no load
if need PV window display 0 when no load, then set PF2 >= |PV| ,
  • E.g when no load,PV display range: -0.2--+0.2, set PF2=0.3 > |PV|=0.2, PV will display 0.0,
  • But if PV > PF2, E.g PV value =0.31> 0.2, PV LED will normal display 0.31.

7.Series Introduction

  • 1 Weight measurement and control *Mixed Batching control
  • Direct Load :1-4 PCS loadcells, 24 Bits A / D
  • Digital Input: Start / Stop and Clear Tare
  • Output::4-20mA / 0-10V , Relay / SSR / Logic output
  • Data Peak value holding function for choice.
  • Communication : RS485 RS232,RJ45(LAN) MODBUS-RTU protocol.
  • Title 5, mypin(LH86-RRRRD)loadcell indicator ,weighing c...
     

*(The above description is the full range of functions included in the TA series.

If required, please select the appropriate model to prevent the function from being unavailable.)

View more
76.64$
3.8
6 reviews 20 sold

mypin(LH86-RRRRD)loadcell indicator ,weighing controller, LED , 1-4 Load Cell Signals Input 4 Relay Output

Delivery edit Brazil

Color: LH86-RRRRD

LH86-RRRRD
1
In stock: 29
Order now
Add to cart
Published: 15.04.2024 16:22 In stock: 29 1.09KViews

Ads from the same category