MYPIN
MYPIN ELECTRICAL CO.,LTD
Add:No7,Lane 5,Str Anhe,Fengyu road ,Zhongshan ,Guangdong ,China
Whatsapp/wechat:18676133547
Products description
1.Products display
2.Technical specification
Model:LM8-RRD
Mypin LM series 4 LED digital display Loadcells indicator
3.Operation/Parameter setting
press and hold SETkey until to enter setting menu.
Press<< /Rst key once, LED flashing
Press << /Rst to shift LED if need
Press Up or Down key to modify data,
Press SET key to confirm data.
Press SET key to read other parameters, and repeat B,C,D steps to modify data if need
Press and hold SET key until to quit menu
4.Weight Adjustment:
When empty (no load),press DOWN key until ‘Oy’ flashing. release DOWN key ; PV LED displays about 0
Follow step 1,placing the weight of this calibration, press UP key until SV LED flashing.
Release UP key.refer parameter setting step to set SV LED data,SV LED data = the weight of this calibration (Equal USP parameter),
E.g,the calibrate weight is 50Kg, Setting SV data=50.00, the unit is Kg, Setting SV data=0.050, the unit is Ton
Refer Page 2(Manual)to lock adjust operation If need
5.Clear tare weight :
press << / Rst key until ‘oy’ flashs to clear tare or short external RST terminal once to clear tare
6.The instrument will auto-return to the measuring estate without any operation for 25 seconds
Note: Zero display (option,refer page 2)
when empty or no load
if need PV window display 0 when no load, then set PF2 >= |PV| ,
E.g when no load,PV display range: -0.2--+0.2, set PF2=0.3 > |PV|=0.2, PV will display 0.0,
But if PV > PF2, E.g PV value =0.31> 0.2, PV LED will normal display 0.31.
7.Series Introduction
1 Weight measurement and control *Mixed Batching control
Direct Load :1-4 PCS loadcells, 24 Bits A / D
Digital Input: Start / Stop and Clear Tare
Output::4-20mA / 0-10V , Relay / SSR / Logic output
Data Peak value holding function for choice.
Communication : RS485 RS232,RJ45(LAN) MODBUS-RTU protocol.
*(The above description is the full range of functions included in the TA series.
If required, please select the appropriate model to prevent the function from being unavailable.)